2 Channel EIS Potentiostat , Double Channel Bipotentiostat CS2350M With Impedance

Categories Dual Channel Potentiostat Bipotentiostat
Brand Name: Corrtest
Model Number: CS2350M
Certification: CE, ISO9001
Place of Origin: Wuhan, China
MOQ: 1 set
Price: USD7600~USD8000/set
Payment Terms: T/T, D/P
Delivery Time: 5-10 working days
Packaging Details: Carton, 53*38*25cm
Name: EIS Potentiostat
Number of channel: 2
Max. current: ±1A in each channel
EIS Module: Yes
EIS frequency: 10uHz~1MHz
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

2 Channel EIS Potentiostat , Double Channel Bipotentiostat CS2350M With Impedance

2-Channel Potentiostat Double Channel Bipotentiostat CS2350M With Impedance


BiPotentiostat/BiGalvanostat with built-in EIS model CS2350M has two sets of built-in independent potentiostat /galvanostat. So it equals that you have 2 sets potentiostat in one instrument. Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data. Each set provides full electrochemical techniques including EIS. Experiments can be conducted simultaneously in each channel. Besides this, the two channels can jointly complete experiment of two-working electrode system such as RRDE and Hydrogen diffusion. CS2350M bipotentiostat is the real double-channel potentiostat. It uses Ethernet connection. EIS module is included in both channels.

Applications

(1) Electrosythesis, electrodeposition (electroplating), anodic oxidation, electrolysis

(2) Electrocatalysis such as Oxygen reduction reaction (ORR), OER, HER, CO2 reduction.
(3) Li-ion battery, solar cell, fuel cell, supercapacitor, advanced function materials, sensor, etc
(4) Corrosion behavior of metals, and anti-corrosion evaluation

(5) Fast evaluation of inhibitor, water quality stabilizer, coating, and cathodic protection efficiency.


Rotating Ring-Disk Electrode (RRDE)

Oxidation/reduction reaction (ORR) study: while measuring the polarization curve of disk electrode in the main channel, apply a constant polarization potential on the ring electrode, and thus detect the intermediate products on the disk electrode. RRDE test becomes the typical method for ORR study. CS2350M can be connected to any RRDE equipment.

Hydrogen Diffusion Test (HDT)

CS2350M bipotentiostat is combined with H-cells. By measuring current of cathode hydrogen charging and hydrogen atoms anode oxidation, it can further calculate the diffusion coefficient of hydrogen atoms in metal and hydrogen flux.


Faradaic efficiency test

In electrocatalysis, the Faradaic efficiency is measured to evaluate the performance of the catalyst. The cable connection is shown in below picture. A constant current will be applied on the disk and occur OER and produce oxygen. A constant voltage is applied on the ring and it occurs ORR and consume oxygen. The Faradaic efficiency can be calculated based on disk current and ring current.


Specifications

Specifications
Support 2-, 3- or 4-electrode systemInterface: Ethernet
Potential control range: Primary Channel: ±10V second Channel: ±10VCurrent control range: ±1A in each channel
Potential control accuracy: 0.1%×full range±1mVCurrent control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz), 3μV (<10Hz)Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A)Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 rangesCompliance voltage: ±21V
Maximum current output: ±1A in each channelCV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000sCurrent increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/msSWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000sAD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μsMinimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHzLow-pass filters: Covering 8-decade
Potential and current range: AutomaticWeight / Measurements: 6.5kg,36 x 30 x16cm
Operating System: Windows 7/8/10/11
Electrochemical Impedance Spectroscopy (EIS)
Signal generator
Frequency range:10μHz~1MHzAC amplitude:1mV~2500mV
DC Bias: -10~+10VOutput impedance:50Ω
Waveform: sine wave, triangular wave and square waveWave distortion:<1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time: minimum:10ms or the longest time of a cycleMaximum:106 cycles or 105s
Measurement delay:0~105s
DC offset compensation
Potential automatic compensation range: -10V~+10VCurrent compensation range: -1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting

Techniques in each channel

Stable polarization

  • Open Circuit Potential (OCP)
  • Potentiostatic (I-T curve)
  • Galvanostatic
  • Potentiodynamic (Tafel plot)
  • Galvanodynamic (DGP)

Transient Polarization

  • Multi Potential Steps
  • Multi Current Steps
  • Potential Stair-Step (VSTEP)
  • Galvanic Stair-Step (ISTEP)

Chrono Method

  • Chronopotentiometry (CP)
  • Chronoamperametry (CA)
  • Chronocaulometry (CC)

Voltammetry

  • Linear Sweep Voltammetry (LSV)
  • Cylic Voltammetry (CV)
  • Staircase Voltammetry (SCV)
  • Square Wave Voltammetry (SWV)
  • Differential Pulse Voltammetry (DPV)
  • Normal Pulse Voltammetry (NPV)#
  • Differential Normal Pulse Voltammetry (DNPV)
  • AC Voltammetry (ACV)
  • 2nd harmonic AC Voltammetry (SHACV)
  • Fourier Transform AC Voltammetry (FTACV)

Electrochemical Impedance Spectroscopy (EIS)

  • EIS vs Frequency (Nyquist, Bode)
  • Galvanostatic EIS
  • EIS vs Potential (IMPE)(Mott-Schottky)
  • EIS vs Time (IMPT)
  • Galvanostatic EIS vs Time

Corrosion Measurements

  • Cyclic polarization curve (CPP)
  • Linear polarization curve (LPR)
  • Electrochemical Potentiokinetic Reactivation (EPR)
  • Electrochemical Noise (EN)
  • Zero resistance Ammeter (ZRA)

Battery test

  • Battery Charge and Discharge
  • Galvanostatic Charge and Discharge (GCD)
  • Potentiostatic Charging and Discharging (PCD)
  • Potentiostatic Intermittent Titration Technique (PITT)
  • Galvanostatic Intermittent Titration Technique (GITT)

Bipotentiostat

  • Hydrogen Diffusion Test (HDT)
  • Rotating Ring Disk Electrode(RRDE)
  • Faradaic efficiencyTest(FE)

Amperometric

  • Differential Pulse Amperometry (DPA)
  • Double Differential Pulse Amperometry (DDPA)
  • Triple Pulse Amperometry (TPA)
  • Integrated Pulse Amperometric Detection (IPAD)

Stripping Voltammetry

  • Potentiostatic Stripping
  • Linear Stripping
  • Staircase Stripping
  • Square Wave Stripping
  • Differential Pulse Voltammetry Stripping
  • Normal Pulse Voltammetry Stripping
  • Differential Normal Pulse Voltammetry Stripping

Extensions

  • Data Logger
  • Electrochemical Stripping/ Deposition
  • Bulk Eletrolysis with Coulometry (BE)
  • Rs Measurement