Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home >

MEASTEK HCTM120KA High Frequency Flexible Current Probe For Power Industry 120KA High Current Probe For Power Transformer Factory

Categories Electronics Test Instruments
Brand Name: MEASTEK
Model Number: HCTM120KA
Payment Terms: T/T,Western Union,MoneyGram
Delivery Time: 5-8 work days
Sensitivity (mV/A): 0.05
Current (KA): 60
Maximum noise (mV Vpp): 5
Attenuation characteristics (%/ms): 0.06
High frequency bandwidth -3dB(MHz): 15
Typical accuracy: 2%
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

MEASTEK HCTM120KA High Frequency Flexible Current Probe For Power Industry 120KA High Current Probe For Power Transformer Factory

MEASTEK HCTM120KA High Frequency Flexible Current Probe For Power Industry 120KA High Current Probe For Power Transformer Factory


Ultra-large range and extreme accuracy

With a sensitivity of 0.05mV/A, it can still maintain extreme accuracy when measuring ultra-large currents with a peak current of 120KA. It is the only choice for high-demand large current measurement scenarios such as factory testing of large power transformer factories and research and development of new energy. ​


Extremely low noise and stable output

With a maximum noise of 5mV Vpp, it provides you with an extremely low noise measurement environment, ensuring stable and reliable measurement data when measuring ultra-large ranges.


Excellent attenuation control

With an attenuation characteristic of 0.035%/ms, it effectively controls signal attenuation in long-term, high-precision measurement tasks, ensures the stability and accuracy of measurement data, and provides you with reliable long-term monitoring data, helping you to conduct a comprehensive performance evaluation of the equipment.​


Advantages of low-frequency ultra-large current measurement

The low-frequency bandwidth -3dB is 0.03Hz, which has significant advantages in measuring low-frequency ultra-large current. For some ultra-high-power equipment running at low frequency, such as new superconducting magnet experimental equipment, large low-frequency motors, etc., it can accurately measure their current and provide key data support for the research and development and operation of equipment. ​


Top quality and after-sales guarantee

The use of top-grade materials and advanced manufacturing processes ensures excellent product quality. At the same time, it provides a full range of after-sales guarantee services, including professional technical support, fast maintenance response, etc., so that you can buy and use without worries.


Specifications

ModelHCTM120KA
Sensitivity (mV/A)0.05
PeakCurrent (KA)120

dI/dt(KA/μs)

40
Maximum noise (mV Vpp)5
Attenuation characteristics(%/ms)0.035
Low frequency bandwidth -3dB(Hz)0.03
High frequency bandwidth -3dB(MHz)15
Typical accuracy

2%

Insulation voltage value

2KV


HCT(S)XXXXA Series Other Technical Parameters

Maximum output voltage

6Vpk

Terminal load

≥100kΩ

Power supply modeUSB 5V (standard adapter)
Operating temperature rangeIntegrator

0℃ - 50℃

Probe ring

0℃ - 100℃

Storage temperature range

-40℃~80℃


Product Description

(Take HCTS0120A as an example)


1) Input interface: current probe test signal input terminal.
2) Output interface: current probe integrator signal output terminal.
3) USB 5V power supply interface: standard USB (type B) interface. (USB power supply cable and power adapter are standard)

4) Test connection diagram.


Mechanical specifications

ModelHCTSXXXXA
Typical value of flexible probe circumference (customizable)

80mm

Typical value of induction ring body diameter

1.6mm

Typical value of flexible probe diameter (customizable)

25mm

Induction loop connection cable length1 M (customizable)
BNC connection cable length1 M or 2 M, 1 M is Standard

Integrator body dimensions

(including BN port dimensions)

About 110(L)*47(W)*30(H)mm
USB cable (AM-BM)About 1.8m
USB output adapterAbout 59mm*30mm*20mm
Probe weightAbout 150g
Box weight (including probe)About 960g


Care And Maintenance

1) Keep the probe clean and dry.
2) If cleaning is required, wipe with a soft dry cloth. Do not use chemical cleaning agents.
3) When the probe is not in use, please put it in the packaging provided and place it in a cool, clean and dry place.
4) When transporting the probe, be sure to put it in the packaging provided by our company to prevent shock.
5) Do not pull the input and output lines hard to avoid excessive twisting, bending or knotting.


Packing List

NameQuantity
Current probe integrator1 piece
Current probe flexible induction coil1 piece
USB output adapter (5V/1A)1 piece
USB power cable1 piece
BNC output cable1 piece
Electronic manual1 serving


Cheap MEASTEK HCTM120KA High Frequency Flexible Current Probe For Power Industry 120KA High Current Probe For Power Transformer Factory for sale
Send your message to this supplier
 
*From:
*To: Shenzhen Knowhow Technology Co.,limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0