Brand Name: Kaixiang
Model Number: AC400-1000KVA
Certification: ISO9001
Place of Origin: China
MOQ: 1 set
Price: negotiable
Payment Terms: Western Union, L/C, T/T
Supply Ability: 40 Sets / Month
Delivery Time: Within 20 working days
Packaging Details: Packaged in container
Model: AC400-1000KVA
Rated power: 1000 KVA
Voltage: AC 400V
Performance: Continuous working
Total tolerance: ±3%
Max Protection Grade: IP54
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Programmable Ac Load Bank 1000 KVA Variable Resistive With 3 Phase

westerbeke testing equipment 1000 KVA for genset testing


Introduction


(1) According to the special requirements of users on site, in the agreement the technical standards of AC400-1000KVA Resistive Inductive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.


Application


1 The system is a self-developed device used for electricity load testing by Kaixiang Technology. It perfectly combines the high voltage dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set.

System mainly consists of resistance load, data collecting, control system, cooling device, etc. The system can test output power and load performance of generator sets.


2 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.


3 System can work with PC software to realize intelligent operation, automatically finish the parameters testing, and create testing data table, curves and reports that can be printed, reduce a lot of manual operation.

Technical specification


System Parameter
Rating voltage/frequency400V, 3 phase 4 wire 50Hz
Max Load Power

Apparent Power: 1000KVA

Resistive Load: 800kW

Inductive Load: 600KVAR

Load Resolution

Resistive Load: 12 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100k,200kW,200kW,200kW

Inductive Load: 11 steps

1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR,200KVAR,200KVAR

Power Factor0.8(lag)
Load Tolerance (each step)±5%
Load Tolerance (overall)±3%
Fan &Control VoltageExternal AC 3 phase 4 line, 380V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication InterfaceRS485,RS232
InsulationF
Max Protection GradeIP21
Duty CycleContinuous
CoolingForced air cooling, by Fan; horizontal inlet air, horizontal exhaust cooling
TransportationHoisting, there are lifting lug in top of casing
ColorGrey RAL7035 or as required
DimensionAbout 2units* 2440 mm×1400mm×1680mm(L×W×H)(
Operating Environment Parameter
WorkplaceIndoor
Ambient Temperature-10℃~+50℃
Relative Humidity≤95%
Atmospheric Pressure86~106kPa
Main features
(1) The load bank is made in container type, with hanging ring on top of container, easy to hoist and transport. There are processes of anti corrosion, anti salty spray and anti fungal according to requirement of easy sea-transported container. The case is sanded and derusted, sprayed with thermo-stable insulating coat, and sprayed with ship special paint outside. Considering cooling, hoisting transportation, components distribution and so on, load bank is treated with over heat and hot-dip galvanizing process, inner paint with high temperature paint. Bolts connect support brackets and bank. Components are well-distributed; each module is distributed with uniformity to make sure the proper weight distribution and cooling.

(2) The container is made by professional container manufacturer, which ensures that the production is strictly in accordance with the container’ manufacturing practice and relevant standards.

(3) The load bank adopts standard container, the overall error of fixing hole is ±2 cm, so that the container can reach the requirements in transportation and storage. The internal structure is a special design, which is divided into independent connection, resistance module, fan cooling, special insulation and so on.

(4) Container load bearing is designed in accordance with container design code. When detecting, use the special thickness gauge TT100 to detect the error of material thickness and design drawing, to ensure that the overall structure of the container meets the requirements of the load bearing. In general, the actual total weight of the load is only about 10T, only 1/3 of the load-bearing design, can ensure the safety and reliability of hoisting and moving.



Product Tags:

lamp load bank

  

diy load bank

  
Cheap Programmable Ac Load Bank 1000 KVA Variable Resistive With 3 Phase for sale
Send your message to this supplier
 
*From:
*To: Hebei Kaixiang Electrical Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0