Sign In | Join Free | My ecer.jp |
|
Categories | CT PT Testing Equipment |
---|---|
Brand Name: | Fanke High-voltage |
Model Number: | FKFA series |
Certification: | ISO9001 |
Place of Origin: | Wuhan ,China |
MOQ: | One Set |
Price: | Negotiable |
Payment Terms: | T/T |
Supply Ability: | 20 sets / month |
Delivery Time: | 15-20working days |
Packaging Details: | Export standard wooden case with fumigation free |
Usage: | CT PT Volt-ampere Characteristics Tester |
Test Items: | CT/PT volt-ampere ,CT/PT ratio, DC resistance, |
Other items: | secondary load test functions, angular phase difference, secondary withstand voltage |
Test output: | 0-2500V adjustable; 0-15A/0-600A/0-1000A |
DC resistance: | test range : 0.1-20Ω |
Secondary load: | test output :0-200A |
Secondary withstand voltage: | test output: 0-2500V |
Accuracy: | < 0.5% |
CT PT Volt-ampere Characteristics Tester , Multifunctional CT PT Testing
I. Product Description:
With the increase requirement of relay protection, the test and check of v-c characteristic carve and the 10% error carve of instrument transformer have became more and more attracting by power system. Based on the absorbing of customers’ suggestion, Fanke has developed a new FKFA voltage-current characteristic comprehensive tester. It adopts high-speed SCM control and inset voltage-up machine, it can test CT voltage-current characteristic, 10% error curve, transformation ratio and polarity on spot. With a special voltage-up transformer, it can do a current-voltage characteristic test for CT/PT within the voltage of 500kV and the current of 1A.
II. Test items and technical data
Input voltage | Maximum output voltage | Maximum output current | Power | measurement accuracy | |||
CT volt-ampere output | 220V | 0—2500V | 15A | 3KVA | < 0.5% | ||
CT ratio output | 220V | 0-8V | 0—600A/1000AOptional | none | < 0.5% | ||
CT ratio measurement | The maximum ratio display: 999.9K: 5 / 1 | < 0.5% | |||||
PT ratio measurement | The maximum ratio display:999.9K:100,150,100/3,100/ | < 0.5% | |||||
DC resistance measurement | The maximum resistance measurement: 0.1-20Ω | Less than 1Ω:3% More than 1Ω: <1% | |||||
angular phase difference | Minimum display: 0.01’ Accuracy::±10’ | Ratio Difference | Minimum display: 0.01% Accuracy:<0.5% | ||||
The secondary load test | Output Current: 0-200A Time:1~5mins | The secondary withstand voltage | output Voltage: 0-2500V Time:1~5mins | ||||
Working temperature | -10~55℃ | Working voltage | AC220V(±20%)50HZ | ||||
Host volume | 420×300×270 | Host weight | 26Kg |
![]() |