Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home > Other Access Control Products >

ALEPH Durable Request To Exit Motion Detector With Wall Or Ceiling Mounted OD22;

Categories Request To Exit Sensor
Model Number: OD-22
Place of Origin: China
Brand Name: ALEPH
Certification: CE ISO
MOQ: 1pcs
Price: Negotiable
Packaging Details: Packaging Details:gift box/color box packaging or according t
Delivery Time: 25-30 days
Payment Terms: TT IN ADVANCE
Supply Voltage: 12-24VDC or VAC .
Supply Current: 18-30mA@12-24VDC,45-80mA@12-24VAC
Detection Type: Passive infrared
Relay Hold Time: 0.5-64 seconds
LED Indication: Red
Operating Temperature: - 14°F to 131°F(- 10° C to 55°C)
Weight: 0. 4lb( 0. 18kg)
Humidity: 0-95% non-condensing
Dimensions: 6.53"Wx1. 57"Hx1. 53"D( 166x40x39mm)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

ALEPH Durable Request To Exit Motion Detector With Wall Or Ceiling Mounted OD22;

ALEPH OD22: REQUEST-TO-EXIT Passive Infrared Sensor


1. SPECIFICATIONS
Supply Voltage12-24VDC or VAC .
Supply Current18-30mA@12-24VDC,45-80mA@12-24VAC
Relay Output2C Contact(N.C/N.O) , 24VDC 1A Max.
Detection TypePassive infrared
Relay Hold Time0.5-64 seconds
LED IndicationRed
RangeCoverage 12x5 ft at 7ft high,30x12 ft at 15 ft high(Adjustment )
Operating Temperature- 14°F to 131°F(- 10° C to 55°C)
Weight0. 4lb( 0. 18kg)
Humidity0-95% non-condensing
Dimensions6.53"Wx1. 57"Hx1. 53"D( 166x40x39mm)

FEATURES FOR ALEPH OD22
• Adjustable second time delay
• High sensitivity
•Micro-based signal processing
2. DIMENSIONS
3. DETECTION PATTERN


4. INSTALLATION
Mounting Procedure
1. Select a mounting location over the center of the door or doors to be covered. Mount the detector on the ceiling wall or door frame.
2. Remove the front cover from the detector.
3. Loosely mount the back cover to the mounting surface using the supplied mounting screws.
4. Aim the detector for the desired coverage.
. Mount the front cover on the detector.
Long Range/Short Range Adjustment
The OD-22 can be set to detect individuals at either a long rang(several steps from the door) or at short range (immediately in front of the door).If the build- ing includes a lengthy approach to the exit doorway and no other foot traffic in the area, choose the long range setting.
Setup and Testing
1. Apply power to the unit.
2. Wait at least 3 min for the detector to settle.
3. Test the unit by walking directly through the coverage area toward the door.
4. Aim the detector up or down if necessary to obtain the proper coverage.
5. Check that the relay latch time is sufficient to adjust if necessary.
6. After confirming proper operation, replace the cover and walk test one more time to ensure the coverage has not changed.
6. WIRING
Latch Time
DIP Switch 1,2, and 3 set the relay time. Latch time is adjustable from 0.5 sec to 64 sec. It indicates the amount of time the relay can remain active after the detector first sees motion.
Table1: Latch Time DIP Switch Settings
Time(sec)Switch 1Switch 2Switch 3
0.5(Default)OFFOFFOFF
1ONOFFOFF
2OFFONOFF
4ONONOFF
8OFFOFFON
16ONOFFON
32OFFONON
64ONONON
Table 2: LED Enable/Disable DIP Switch Settings
Switch 4Function
OFFDisabled
ONEnabled (Default)
Table 3:Relay Mode DIP Switch Settings
Switch 5Function
OFFFail Secure
ONFail safe(Default)
Table 4:Resettable/Non-resettable DIP Switch Settings
Switch 6Function
OFFNon-resettable
ONResettable (Default)
7. TROUBLE SHOOTING AND MAINTENANCE
TROUBLETROUBLE CAUSEREMEDY
the unit does not power upNo or low input power.Apply proper input voltage.
Input power polarity reversed.Correct wiring polarity.
Alarm LED does not lightthe LED jumper is set to “LED OFF”.Set LED jumper to “LED ENABLE”
Incorrect sensor mounting heightIncrease /decrease mounting height
LED indicates light,no signal outputIncorrect wiring at output terminalsCorrect wiring fault.
Lightning damageReplace sensor.
Unit continues to operate after the input power has been disconnected.The wire to the “V-” power input was discon- nected, the “V+” is still connected.Disconnect wire from the “V+” power input.

MAINTENANCE


INSPECTION: An inspection of this unit should be made periodically, consisting of but not limited to all mounting, wiring
and the condition of the interior area and components.
CLEANING: Clean the plastic parts of this unit with a soft, clean, cloth dampened with water.
TESTING: This unit should be tested routinely for proper operation. At a minimum,operation should be fully checked yearly.

Cheap ALEPH Durable Request To Exit Motion Detector With Wall Or Ceiling Mounted OD22; for sale
Send your message to this supplier
 
*From:
*To: Ain Technology (Shenzhen) Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 