Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home > Energy Meters >

Sewage Wastewater Flow Meter With 4 - 20ma Output / Modbus RS485 Standard 220VAC Power Supply

Categories Electromagnetic Flow Meter
Brand Name: Kacise
Model Number: GXEFM2000
Certification: certificate of explosion-proof, CE
Place of Origin: China (Mainland)
MOQ: 1pcs
Price: Negotiable
Payment Terms: L/C, D/A, T/T, D/P, Western Union, MoneyGram
Supply Ability: 1000 Pieces per Week
Delivery Time: 5-8 work days
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Type: Sewage Wastewater Flow Meter
output: 220VAC Power Supply
Product: Electromagnetic Flow Meter
Power supply: 220VAC Power Supply
Product name: Electromagnetic Flowmeter
Output: 4-20mA /RS485/HART/PROFIBUS DP
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Sewage Wastewater Flow Meter With 4 - 20ma Output / Modbus RS485 Standard 220VAC Power Supply

Kacise Digital Sewage Waste Water Electromagnetic Flowmeter with 4-20ma output or Modbus RS485 ​

Application field


Petroleum, Chemical, Metallurgy, Textile, Papermaking, Environmental protection, Food industry and Municipal administration, Water conservancy construction, Heating heating engineering, River dredging and other fields.


FeaturesFully welded maintenance-free sensor
Flange version with full bore flow tube
Standard as well as higher pressure ratings
Large diameter range from DN15~3000 with rugged liners approved for drinking water
Industry specific insertion lengths
Modular constructionThe measurement system consists of a flow Sensor and a signal converter. It is available as compact and as separate version
Compact versionWith 511B converter: 110~240Vac Power
With 521B converter: 18~36V DC Power
With W800L/W800W: Battery Power
Remote version

In wall mount version with 211B converter

(110~240Vac or 221B converter 18~36V DC

With W800F converter: Battery Power
Measurement range-12…+12m/s /-40...+40ft/s

Measuring system


Measuring principleFaraday’s law
Application rangeElectrically conductive fluids
Measured Value
Primary measured valueFlow velocity
Secondary measured valueVolume flow

Measuring accuracy


Reference conditionsFlow conditions similar to EN 29104
Medium: water
Electrical conductivity: ≥300μs/cm
Temperature: +10~+30℃/+50~+80℉

Inlet setion: ≥5DN
Operating pressure: 1Bar/14.5psig
Flow Meter AccuracyStandard: 0.5% of rate
Optional: 0.2% of rate

Operating conditions


Temperature
Process temperatureHard rubber liner: -5~+60℃
Polypropylene liner: -5~+90℃
PTEF liner: -5~+120℃
Ambient temperatureStandard (with aluminum converter housing)

-20~+60℃ (Protect electrics against self-heating

with ambient temperature above 55℃

Stroage temperature-20~70℃
Pressure
EN 1092-1DN2200~3000: PN2.5
DN1200~2000: PN6
DN200~1000: PN10
DN65~150: PN16
DN10~50: PN40
Other pressure on request
ISO insertion lengthOptional for DN15~600
ASME B16.51~24”: 150lb RF
Other pressure on request
JISDN10~1000/ 2~40”: 10K
Other pressure on request
Pressure dropNegligible

Installation conditions


InstallationTake care that flow sensor is always fully filled
For detailed information see chapter “Cautions for installation”
Flow directionForward and reverse
Arrow on flow sensor indicates positive flow direction
Inlet run≥5 DN
Outlet run≥2 DN

Process connection


Flange
EN1092-1DN25~3000 in PN6~40
ASME1~120” in 150 lb RF
JIS25~1000 in 10~20k
Design of gasket surfaceRF
Other sizes or pressure ratings on request

Ordering information


Model Suffix Code Description
GXEFM3000-1200-Com-4mA-Hart-DC-Pt-Teflon1-GR-D1400-Exd IIC T6 Gb 
Diameter-XXXX         Four Digitals: for example:0010: 10mm: 0015:15mm 0100: 100mm 1000: 1000mm
Transmitter-Com        Compact type
-Rem        Remote type
-Bat        Battery power supply type
-PRO        process control type
Signal Outpt-N       No output
-4mA       4-20mA
-Pul       1~5KHz pulse
-4Pul       4~20mA / 1~5KHz
Communication-N      No communication
-Hart      HART
-MOD      MODBUS-RTU
-PRO      PROFIBUS
-GPRS      GPRS net
-CDMA      CDMA net
-WHRT      Wireless HART
-Other      special order
Power Supply-AC     85V~250Vac@46~63Hz
nominal 20W
-DC     20~36VDC nominal 20W
-Bat     Battery power supply
-Bat+     Battery +12Vdc dual power supply
Other     special request
Electorde Material-316L    Stainless steel 316L
-HasB    Hastelloy B
-HasC    Hastelloy C276
-Pt    Platinum
-Ta    Tantalum
-Ti    Titanium
-WC    wolfram carbide
Liner material-Rub1   Neoprene(-20-60℃)
-Rub2   Neoprene(-20-90℃)
-Tef1   polytetrafluroethylene(-30-120℃)
-Tef2   polytetrafluroethylene(-20-160℃)
-P   Polyurethane
-FVMQ   FVMQ
-PFA   DFA
-ETFE   Ethylene tetraflurorethylene
Grounding Ring-N  No grounding ring
-GR  Grounding ring
-GE  Grounding Electrode
Wet part Connection attribute-DXX DXX: D06, D10, D16, D25,D40 D06: DIN PN6:
D10: DIN PIN10D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 etc
-AX AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600#
-JX JX: J1, J2, J3 J1: JIS10K;
J2: JIS 20K; J3: JIS 30K
-WF Wafer connection (available for DN2.5; DN6 flow meter) Body material: stainless steel
-TR Tri-Clamp for sanitary type (Body material: stainless steel)
Explosive-proof grade-Exd IIC T6 GbExd IIC T6 Gb
-Ndon't need