Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home > Transformers >

Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test

Categories Transformer Test Equipment
Brand Name: AI
Model Number: TDT
Certification: ISO
Place of Origin: China
MOQ: 1 Set
Price: Negotiable
Payment Terms: T/T, Western Union, L/C
Supply Ability: 100000 sets per month
Delivery Time: 15 days
Packaging Details: Plywood case
Power supply: 220V±10%
Display: LCD
Keyword: Tan Delta Test, Loss Angle Test, Dissipation Factor Test
Weight: 28KG
Size: 350*270*270mm
High output: 0.5KV~10KV(12KV can be customized)
Warranty: 1 Year
Maximum current: 200mA
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test

Transformer Tan Delta Test Equipment


I.Introduction:

TDT Tan Delta Test Equipment is an integrated structure, there is a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor built-in;

This Loss Angle Test Equipment can also supply high voltage source for testing.

Frequency can be changed to 50Hz, 47.5Hz52.5Hz,45Hz55Hz, 60Hz, 57.5Hz62.5Hz, 55Hz65Hz; thus, this power factor tester can avoid interference of power frequency;

This dissipation factor test equipment can also be used as power supply;



II.Specifications:

No.Item NameTransformer Tan Delta Test Loss Angle Test Dissipation Factor Test Equipment
1Use conditions-15℃~40℃RH<80%
2Anti-interferenceFrequency conversion
3PowerAC 220V±10%Allowable generator
4High output0.5KV~10KVEvery 0.1kV
Precision2%
Maximum current200mA
Capacity2000VA
5Self-excited powerAC 0V~50V/15A

45HZ/55HZ 47.5HZ/52.5HZ

55HZ/65HZ 57.5HZ/62.5HZ

Automatic double frequency

6Resolving powertgδ: 0.001%Cx: 0.001pF
7Precisiontgδ:(Reading*1.0%+0.040%)
Cx :(Reading*1.0%+1.00PF)
8Measuring rangetgδUnlimited
Cx15pF < Cx < 300nF
10KVCx < 60 nF
5KVCx < 150 nF
1KVCx < 300 nF
CVT testCx < 300 nF
9CVT range10~10000
accuracy0.1%
Resolving power0.01
10Dimension350*270*270mm
11Memory sizeThe 200 group supports U disk data storage
12Weight

28 Kg


Spares of Transformer Tan Delta Test Loss Angle Test Dissipation Factor Test Equipment


NO.NameQuantityUnit
1Main Unit1Set
2Accessory case1PC
3Red HV test cable1Root
4Black LV test cable1Root
5AC220V power cable1Root
6

CVT self-excited power cable (attached)


1Root
7

Ground wire


1Root
8Fuse, printer paperSpare
Cheap Transformer Test Equipment for Tan Delta Tester Dissipation Factor Test for sale
Send your message to this supplier
 
*From:
*To: Advanced Instruments Co.,Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0