Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home > Other Electrical Equipment >

40times/min Heavy Current Ignition Tester Flammability Testing Equipment

Categories Flammability Testing Equipment
Brand Name: HeJin
Model Number: HAI-1
Certification: calibration certificate(cost additional)
Place of Origin: China
MOQ: 1 set
Price: Negotiatable
Payment Terms: L/C, T/T
Supply Ability: 10 set per month
Delivery Time: 30 days
Packaging Details: Plywood
Product name: Heavy Current Ignition Tester HAI-1
Arc strike speed: 40 times/min
Arc strike times: 0-9999 can be preset
Working voltage: 220V/50Hz
Standard: IEC 60950-1,IEC60947-1,IEC730-1
Function: Flammability Testing Equipment
Electrode separation velocity: 254±25㎜/s
Control operation mode: Electrical control, button operation
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

40times/min Heavy Current Ignition Tester Flammability Testing Equipment

Flammability Testing Equipment Heavy Current Ignition Tester For Arcing Resistance Test Of Electric


Standard:

IEC 60950-1 Information technology equipment - Safety - Part 1: General requirements.

IEC60947-1 Low-voltage switchgear and controlgear - Part 1: General rules.

IEC60730-1 Automatic electrical controls -Part 1: General requirements.


Application:

It is suitable for arcing resistance test of electric and electronic products, household appliances and its materials. The working principle is to simulate the electric leakage on the insulator which may cause among different polar of live parts or between live parts and grounded (earthed) metal parts. It is used to measure and assess the arc resistance performance of insulator under the prescribed voltage.


Test sample:

Information technology equipment, low voltage switch and control equipment parts.Flammability Testing Equipment.


Feature:

Heavy current ignition tester adopts dual electrodes. With specific current (33A) and power factor (COSφ0.5), according to a certain arc strike speed (254mm/s) and repetition frequency (40 times/min), repeatedly arc strike to 200 times on the surface of specimen. The large current arc ignition performance (HAI) can be assessed according to whether the sample can be ignited. The smaller of the grade number, the more difficult for burning material.


Parameters:

Working voltage220V/50Hz(Flammability Testing Equipment)
Control operation modeElectrical control, button operation
Arc strike current and power factorWhen the power factor is 0.5, the current is 33A±0.5A
Arc strike speed40 times/min
Electrode separation velocity254±25㎜/s
Arc strike times0-9999 can be preset
Electrode material

Static electrode—copper,dia.Ф3.5mm (Ф3.2)×152mm,top bevel angle 30°

Moving electrode—stainless steel,diaФ3.5mm(Ф3.2)×152mm, top cone angle 60°

Electrode included angleForm 45° with level,electrode head radius of curvature 0.1mm
Test procedureAutomatic control, independent exhaust
LightingEquip with lighting in the test chamber, with control
Test chamber and dimensionLWH:800×700×1600mm,300kg