Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home > High Bay Lights >

Arrangement For Impact Test Light Testing Equipment

Categories Light Testing Equipment
Brand Name: SHC
Model Number: SC-AT815
Certification: CNAS、TUV、ITS、CSA、BV、SGS (cost additional)
Place of Origin: China
MOQ: 1 unit
Price: USD 300-1000 piece
Payment Terms: T/T, Western Union, MoneyGram, D/A
Supply Ability: 999 units per month
Delivery Time: in 15 work days
Packaging Details: Carton
Standard: IEC 60598-1 Clause 8.15
Name: Arrangement For Impact Test For Handlamps
Steel jaws width: 15mm
Steel jaws radius: 2.5 mm
The force applied through the jaws: 100 N
Test environment: heating cabinet
Temperature: 100±2℃
Customize: OEM, ODM
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Arrangement For Impact Test Light Testing Equipment

IEC 60598-1 Clause 8.15 Arrangement For Impact Test For Handlamps


Technical parameters:

Steel jaws width15mm
Steel jaws radius2.5 mm
The force applied through the jaws100 N
StandardIEC 60598-1 clause 8.15

Product information:

This test apparatus is designed and manufactured according to the standard requirements of IEC 60598-1 clause 8.15.1 for handlamps having a handle or shell of flexible material, such as rubber or polychloroprene, compliance shall be checked by the following test.

The parts of the handlamp which are gripped in normal use, are subjected to a pressure test in an apparatus similar to that shown in figure 3, the test being made in a heating cabinet maintained at a temperature of 100±2℃.

The sample is clamped between steel jaws, having a cylindrical face of 25 mm radius, a width of 15 mm and a length of 50 mm. The corners are rounded with a radius of 2.5 mm.

The sample is clamped in such a way that the jaws press against it in the area where it is gripped in normal use, the centre line of the jaws coinciding as nearly as possible with the centre of this area.

The force applied through the jaws is 100 N.

After 1 h, the jaws are removed and the sample shall show no damage.