Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home > Explosion-proof Lights >

100N Impact LED Light Testing Equipment IEC 60598 1 Clause 8.15.1

Categories LED Light Testing Equipment
Brand Name: KingPo
MOQ: 1
Place of Origin: China
Certification: ISO 17025 Calibration certificate
Price: To be quoted
Packaging Details: safety box
Delivery Time: 20~25 working days
Payment Terms: 100% TT in advance
Supply Ability: 3~5 units per month
standard: IEC 60598-1 clause 8.15.1
jaws materail: steel
jaws width: 15mm
jaws radius: 2.5 mm
force applied: 100N
test sample: handlamps having a handle or shell of flexible material
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

100N Impact LED Light Testing Equipment IEC 60598 1 Clause 8.15.1

100N Impact LED Light Testing Equipment IEC 60598 1 Clause 8.15.1


IEC 60598-1 clause 8.15.1 Arrangement For Impact Test


Product information:

This test device is designed and manufactured according to the standard requirements of IEC 60598-1 clause 8.15.1 for handlamps having a handle or shell of flexible material, such as rubber or polychloroprene, compliance shall be checked by the following test.

The parts of the handlamp which are gripped in normal use, are subjected to a pressure test in an apparatus similar to that shown in figure 3, the test being made in a heating cabinet maintained at a temperature of 100±2℃.

The sample is clamped between steel jaws, having a cylindrical face of 25mm radius, a width of 15 mm and a length of 50 mm. The corners are rounded with a radius of 2.5mm.

The sample is clamped in such a way that the jaws press against it in the area where it is gripped in normal use, the centre line of the jaws coinciding as nearly as possible with the centre of this area.

The force applied through the jaws is 100N.

After 1 h, the jaws are removed and the sample shall show no damage.


Technical parameters:

Steel jaws width

15mm

Steel jaws radius

2.5 mm

The force applied through the jaws

100 N

Standard

IEC 60598-1 clause 8.15


IEC 60598-1 Clause 8.15 Arrangement Light Testing Equipment For Impact Test 0