Sign In | Join Free | My ecer.jp |
|
Categories | Liquid Chromatography Instrument |
---|---|
Brand Name: | Wayeal |
Model Number: | LC3200 |
Certification: | ISO, CE |
Place of Origin: | Anhui, China |
MOQ: | 1 |
Price: | Negotiation |
Payment Terms: | L/C, T/T |
Supply Ability: | 30 Pieces Per Month |
Delivery Time: | 30 days |
Packaging Details: | Wooden Case |
Product Name: | HPLC Liquid Chromatography Instrument |
Detector: | UVD/DAD/ELSD/RID/FLD |
Wavelength Length: | 188 - 900 nm |
Lamp: | Tungsten lamp |
Linearity: | 2.5AU |
Drift: | 1.0 × 10-4 AU/h |
Company Info. |
Anhui Wanyi Science and Technology Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
Quaternary Pump HPLC Cromatografía with UV Detector High
Performance Liquid Chromatography Instrument
Introduction of Liquid Chromatography Instrument
High Performance Liquid Chromatography (HPLC) is a form of column chromatography that pumps a sample mixture or analyte in a solvent (known as the mobile phase) at high pressure through a column with chromatographic packing material (stationary phase). HPLC has the ability to separate, and identify compounds that are present in any sample that can be dissolved in a liquid in trace concentrations as low as parts per trillion.
Parameters of Liquid Chromatography Instrument
Quaternary Pump HPLC Cromatografía with UV Detector High Performance Liquid Chromatography Instrument | |
Pump | |
Gradient | Quadratic Low Pressure |
Flow Rate Range | 0-11.0000mL/min |
Min Injection Unit | 0.0001mL/min |
Flow Rate Error | ±0.2% |
Flow Rate Repeatability | ≤ 0.08% RSD |
Gradient Stability | < 0.5% RSD |
Max Operating Pressure | 42MPa |
In-line Degassing | |
Column Oven | |
Temperature Range | 4 ℃ ~ 85 ℃ |
Temperature Stability | ≤±0.02 ℃ |
Autosampler | |
Sampling Volume | 0.1-20.0uL (in 0.1μL increments) |
Sample Capacity | 120 vials, 2ml vial |
Linearity | r > 0.9999 |
Cross-contamination | < 0.002% |
Sampling Error | ±0.2μL (sampling volume 10μL) |
Sampling Repeatability | < 0.3% RSD |
Injection Speed | 15s |
UV Detector | |
Wavelength Range | 188 - 900 nm |
Wavelength Error | ≤ ±0.5 nm |
Wavelength Repeatability | ≤ ±0.1 nm |
Baseline Noise | 0.8 × 10-5 AU |
Drift | 1.0 × 10-4 AU/h |
Linearity | 2.5 AU |
Features of Liquid Chromatography Instrument
1. Two optional modes: binary high pressure and quaternary low
pressure. The binary high pressure mode is equipped with a solvent
selector valve, which can be extended from binary to quaternary
system, greatly improving the flexibility of system configuration.
2. Wavelength scaning: the absorption spectrum can be scanned in the entire range of the light source.
3. A variety of detectors available, such as DAD, ELSD and FLD.
4. Dual-wavelength detection, two wavelengths canbe detected at the same time.
![]() |