Product name: | 150 ° C Shoe Material High Temperature Insulation Tester EN ISO 20344 |
Sandy Height: | ≥5 cm |
Sand size: | 0.3 ~ 1.0 mm |
Heating power: | 2.5 KW |
Hot plate maximum temperature: | 250 ℃ |
Heat transfer medium: | dia 5 mm steel ball, the total mass of 4 kg |
Test temperature: | 150 ± 5 ℃ or 250 ± 5 ℃ |
Temperature control accuracy: | ± 2 ℃ |
Power: | AC 220V, 5 A. |
Key words: | 150 ° C Shoe Material High Temperature Insulation Tester EN ISO 20344 |
Company Info. |
Dongguan Zhongli Instrument Technology Co., Ltd. |
Verified Supplier |
View Contact Details |
Product List |
150 ° C Shoe Material High Temperature Insulation Tester EN ISO 20344
Tester Introduction:
The instrument used to test the entire shoe, sole material (such as rubber, polymer) the ability of high temperature insulation.
Meeting standards: EN ISO 20344
Technical Parameters:
Sandbox size | 400 × 400 × 80 mm |
Sandy Height | ≥5 cm |
Sand size | 0.3 ~ 1.0 mm |
Test temperature | 150 ± 5 ℃ or 250 ± 5 ℃ |
Heat transfer medium | dia 5 mm steel ball, the total mass of 4 kg |
Copper / copper-nickel thermocouple | Weld a copper disc of 2 ± 0.1 mm in diameter and 15 ± 1 mm in diameter |
Temperature measurement and recording device | with the use of copper discs, with temperature compensator |
Temperature control accuracy | ± 2 ℃ |
Hot plate maximum temperature | 250 ℃ |
Heating power | 2.5 KW |
Dimensions | about 500 × 500 × 360 mm (L × W × H) |
Weight | about 53 kg |
Power | AC 220V, 5 A. |
Test principle:
The sandbox is heated to 150 ° C, so that the sand covers the contact area between the sample upper and the sole, and records the temperature change of the insole within 30 minutes to the nearest 0.5 ° C.
![]() |