Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home > Apparel & Textile Machinery >

LoRa Gateway Supports ADR Higher Rate Lower Energy Consumption Supply Voltage 12V ESD 8000V

Categories Wireless Pressure Transmitter
Brand Name: Kacise
Model Number: LoRa Gateway
Certification: certificate of explosion-proof, CE
Place of Origin: China (Mainland)
MOQ: 1pcs
Payment Terms: T/T, Western Union, MoneyGram
Delivery Time: 5-8 working days
Packaging Details: each unit has individual box and all boxes are packed in standard packages or customers requests available
Supply Ability: 3000 Piece/Pieces per Month molasses flow meter
Supply voltage: 12V
Operating voltage: 5V
Operating current: 562mA
Ethernet speed: 100Mbps
Frequency range: 490 / 868 / 915MHz
RF transmit power: 17dBm
Emission frequency vs temperature: ±3ppm
Transmit power vs temperature: ±3dB
Operating temperature: -10~+60℃
ESD: 8000V
Base station chassis size (excluding antenna): 155*151*38mm
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

LoRa Gateway Supports ADR Higher Rate Lower Energy Consumption Supply Voltage 12V ESD 8000V

LoRa Gateway Supports ADR Higher Rate Lower Energy Consumption Supply Voltage 12V ESD 8000V


1.Introduction

LoRa is a wireless spread spectrum communication technology, and LoRaWAN is a LoRa-based communication protocol.

As shown in the figure above, LoRaWAN defines Node, Gateway and Server,a total of 3 entities, at the same time, defines the communication interface between entities, and in order to ensure the "interconnection" of global manufacturers' products, the LoRaWAN protocol (currently, the latest versionis V1.0.2) and the frequency bands of various countries (regions) are disclosed.

LoRaWAN has become one of the industry standards for the Internet of Things with its "standard, open, free and secure", and it is believed that it will be as successful as the IP protocol 30 years ago.

2.Feature

  • Support web parameters, which greatly improves ease of use and stability.
  • Multi-channel: Based on SX1302 chip, 8 channels, up to 10,000 LoRa nodes.
  • Long distance: The open environment can cover an area with a radius of 5km.
  • Adaptive: Support ADR, higher rate, lower energy consumption, easy expansion.
  • Compatibility: Fully compatible with LoRaWAN, "interoperable" with equipment from various manufacturers.
  • High quality: industrial-grade ARM platform, efficient and stable, based on Linux system, mature and easy to use.

3.Technical Specifications

Parameter items

Test

conditions

MinimumTypicalMaximumUnit
Overall electrical parametersSupply voltage91224V
Operating voltageARM+SX13024.7555.25V
Operating current450562900mA
Electrical characteristics of the module interface

Ethernet

speed

10M100Mbps

Isolation

voltage

strength

Leakage

current<5mA,

temperature < 95%

2.5KVDC
LoRa RF parametersFrequency range490 / 868 / 915MHz
RF transmit power61727dBm
ModulationSpread spectrum modulation

Emission frequency

vs temperature

-40 to +85°C±3ppm

Transmit power vs

temperature

±3dB
Maximum operating conditions

Operating

temperature

-10+60
ESD8000V
Base station chassis size (excluding antenna)155*151*38mm

4.Power supply and installation


As shown in the figure below, use the "12V Power Adapter" (gateway accessory) to power the "Gateway" and connect to the Internet/Intranet through the "Router".


5.Dimensions


6.Rate and frequency


6.1 Rate sensitivity distance

As shown in the table below, the base station supports 6 communication rates.The higher the rate, the closer the effective communication distance, and the lower the rate, the longer the effective communication distance.

SFData Rate (bps)Sensitivity (dBm)Range (Km)10Bytes payload Time on Air(ms)
75469-130.0265
83125-132.54100
91758-135.06200
10977-137.58370
11537-140.011740
12293-142.5141400

In order to simplify the use, the communication rate is dynamically set by the server, and its rules are: the node close to the base station and the signal is good, the high rate is adopted, and the node far away from the base station and the signal is weak, the low rate is used. This is called ADR (Adaptive Data

Rate) technology.


6.2 LoRa Signal indicators

Field strength value RSSI: normal value -120 ~ -10 dBm, below -125 dBm packet loss rate will be higher.

SNR: Limit value -20 dB.


6.3 Communication frequency


regionabbreviationUplink:Band+Rate+BandwidthRX2 downlink:Band+Rate+Bandwidth
RX1 downlink: band + rate + bandwidth
ChinaCN470

486.3/486.5/486.7/486.9/487.1/487.3/487.5/487.7

SF7BW125 – SF12BW125

505.3SF12BW125

506.7/506.9/507.1/507.3/507.5/507.7/507.9/508.1

SF7BW125 – SF12BW125

North

America

US915

903.9/904.1/904.3/904.5/904.7/904.9/905.1/905.3

SF7BW125 – SF10BW125

923.3SF12BW500

923.3/923.9/924.5/925.1/925.7/926.3/926.9/927.5

SF7BW500 – SF10BW500

EuropeEU868

867.1/867.3/867.5/867.7/867.9/868.1/868.3/868.5

SF7BW125 – SF12BW125

869.525SF12BW125

867.1/867.3/867.5/867.7/867.9/868.1/868.3/868.5

SF7BW125 – SF12BW125

AustraliaAU915

916.8/917.0/917.2/917.4/917.6/917.8/918.0/918.2

SF7BW125 – SF12BW125

923.3SF12BW500

923.3/923.9/924.5/925.1/925.7/926.3/926.9/927.5

SF7BW500 – SF10BW500

Asia 1

Singapore

Malaysia

Japan

AS923

AS1

922.0/922.2/922.4/922.6/922.8/923.0/923.2/923.4

SF7BW125 – SF12BW125

923.2SF10BW125

922.0/922.2/922.4/922.6/922.8/923.0/923.2/923.4

SF7BW125 – SF12BW125

Asia 2

AS923

AS2

923.2/923.4/923.6/923.8/924.0/924.2/924.4/924.6

SF7BW125 – SF12BW125

923.2/923.4/923.6/923.8/924.0/924.2/924.4/924.6

SF7BW125 – SF12BW125

KoreaKR920

922.1/922.3/922.5/922.7/922.9/923.1/923.3

SF7BW125 – SF12BW125

921.9SF12BW125

922.1/922.3/922.5/922.7/922.9/923.1/923.3

SF7BW125 – SF12BW125

IndiaIN865

865.0625/865.4025/865.9850

SF7BW125 – SF12BW125

866.550SF10BW125

865.0625/865.4025/865.9850

SF7BW125 – SF12BW125

RussiaRU864

864.1/864.3/864.5/864.7/864.9/868.9/869.1

SF7BW125 – SF12BW125

869.1SF12BW125

864.1/864.3/864.5/864.7/864.9/868.9/869.1

SF7BW125 – SF12BW125


7 Communicate with nodes


In general, the base station and node communicate well. If the communication fails, troubleshoot the cause in the following order:

probabilityphenomenonsettle
30%

The base station cannot

receive node packets

The base station is in the same frequency band as the node
30%

The base station is not

connected to Loravan Seifer

Register the base station with the LoRaWAN Server

The LTE (4G) base station

cannot connect to the server

1 Check whether the 4G SIM card is in

arrears;

2 Check if the 4G SIM card is in poor contact;

3 Check the local 4G signal quality;

20%

The node is not connected to

Loravan Seifer

Register the node with the LoRaWAN Server
5%The distance is too farReduce the communication distance between the base station and the node
4%Signal interference is severeSwitch the base station and node frequency
1%Hardware damageContact the after-sales service

8.Interface definition

The base station strictly follows the LoRaWAN GSID (Gateway to Server Interface Definition) standard.


Generally speaking, as long as the following 3 parameters are set, the base

station can be connected to "any" LoRaWAN Server.

1) server_address (Explanation: the domain name address of the server, e.g.

router.cn.thethings.network)

2) serv_port_up (Explanation: UDP port uploaded to the server by the base

station, default is 1700)

3) serv_port_down (Explanation: The server goes down to the UDP port of the

base station, the default is 1700)


The protocol stack of the LoRaWAN GSID is shown in the following figure



9.Common Problems and Solutions


Q: Why is the packet loss rate high between base stations and nodes?

A: Please check if the antenna is properly installed and matched.

Base station <--> whether the Internet/intranet network environment of the

server is smooth.

Whether the receiving environment is harsh, such as: obstacles are very

dense and there are strong interference sources.

Whether the node has ADR turned on to reduce co-channel interference.

Q: What should I pay attention to in the proximity test?

A: Base stations and nodes should be more than 10 meters apart as much as

possible.

Indoor base station Install the "fiberglass" antenna <--> node to remove the

antenna

Indoor base station Install a "glue stick" antenna <--> node to install a "glue

stick" antenna

Q: 4G communication quality is poor and packet loss rate is high.

A: Please check if the 4G antenna is installed correctly and matched.

Check your local 4G signal quality.


10.Configuration Parameters

Step 1: Prepare your network environment



The default value of the base station is 192.168.1.99, please set the PC to 192.168.1.100, and connect the base station and the PC directly through the network cable.


If you want the base station to be directly connected to the LoRaWAN Server in the LAN, you can set the base station to a static IP, at this time, be sure to record the IP address (as shown in the figure above 172.16.0.123), otherwise,the PC will fail to connect to the base station!

Principle: The PC with the configuration parameters must be on the same network segment as the base station (for example, 192.168.0.x or 172.16.0.x).


Step 2: Log in to the base station using a browser

Enter the base station IP address, user=guest, password=rimelink, and click "Login".



Step 3: Configure parameters

Support settings: server address and port, frequency, power, IP address. Click "OK" and it will take effect immediately!.


11.View logs



Diagnosis 1: Whether the node reports data

RF packets received by concentrator: 131 <-- Received 131 LoRa packets

Diagnosis 2: Whether the server responds to the Gateway handshake packet

(Firewall Enabled)

PULL_DATA sent: 5(100.00% acknowledged) <-- The base station and the

server have 5 handshakes normally

Diagnosis 3: Whether the server delivers node data

RF packets sent to concentrator: 2 (46 bytes) <--The base station transmits

two downlink LoRa packets

Cheap LoRa Gateway Supports ADR Higher Rate Lower Energy Consumption Supply Voltage 12V ESD 8000V for sale
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0