Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A

Categories Mini Circuit Breaker
Brand Name: KRIPAL
Model Number: UKL1
Certification: CE
Place of Origin: China
MOQ: 1000 pcs
Price: negotiable
Payment Terms: T/T, L/C
Supply Ability: 200000 pcs per month
Delivery Time: 20 days and depends on ordering quantity
Packaging Details: 12 poles packed in one small box and then in carton
Poles available: 2P, 4P
Ampere: 16A 25A 40A 63A
Residual protection: Yes
Type: mini circuit breaker
leakage current: 10 30 100 300 500mA
Standard: IEC1008 EN61008
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A


Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A


KRIPAL has the design patent for these items


A residual-current device (RCD), or residual-current circuit breaker (RCCB) is an electrical wiring device that disconnects a circuit whenever it detects that the electric current is not balanced between the energized conductor and the return neutral conductor. Such an imbalance may indicate current leakage through the body of a person who is grounded and accidentally touching the energized part of the circuit. A lethal shock can result from these conditions. RCCBs are designed to disconnect quickly enough to prevent injury caused by such shocks. They are not intended to provide protection against overcurrent (overload) or all short-circuit conditions.


Techinical data:


A. Conform to standard: GB16916.1
B. Rated voltage (Ue): 230V/400V; 50/60Hz
C. Rated current (A): 16, 25, 40, 63 A (2 poles and 4poles)
D. Rated leakage current: 10, 30, 100, 300, 500Ma
E. Electric life: ≥ 4000 times (on-off)
F. Mechanical life: ≥ 2000 times (on-off)
G. Case protection grade: IP40 after installing



Mechanical parameter

A. Installation mode: At the DIN rail of standard IEC
B. Terminal wiring capability: Conductor 1-25 mm
C. Width of shell: 2 poles 36mm; 4 poles 72 mm



Main characteristic

A. Various current specifications of leakage action ca easily ensure selective protection.
B. Inaccurate action resulting form the switch operation of electronic equipment can be avoided
C. Unless specified otherwise, the width of two-poles switch is two modules, four-poles(3P+N) is four modules


Specifications:

Technology Specification & Electrical Specification
Electric standardIEC1008 EN61008
Trip timeNon-time delay; Minimal 10ms time delay
Rated voltage230V/400V
Rated surplus operating current10; 30; 100; 300mA, 500mA
Selection grade3
Poles2pole 4pole
Rated current16A, 25A, 40A, 63A
Tripping characterB, C, D characteristic curve
Terminal wiringconductor 1-25 mm2
Environment capabilityAccording to the IEC 1008 standard
Case protection gradeIP40 after installation
Electric lifeNot less than 4000 times of breaking and closing
Mechanical lifeNot less than 2000 times of breaking and closing
Mechanical Parameter
Installation modeInstallation at the DIN guide rail of 35mm
Terminal block capacityGeneral thickness 0.8-2mm



Main benefits:

High quality
Complete range


Instantaneous tripping current:

International Standard--- IEC 60898-1 and European Standard EN 60898-1 define the rated current In of a circuit breaker for low voltage distribution applications as the maximum current that the breaker is designed to carry continuously (at an ambient air temperature of 30 °C). The commonly-available preferred values for the rated current are 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A, 50 A, 63 A, 80 A, 100 A,[5] and 125 A (Renard series, slightly modified to include current limit of British BS 1363 sockets). The circuit breaker is labeled with the rated current in amperes, but without the unit symbol "A". Instead, the ampere figure is preceded by a letter "B", "C" or "D", which indicates the instantaneous tripping current — that is, the minimum value of current that causes the circuit breaker to trip without intentional time delay (i.e., in less than 100 ms), expressed in terms of In:

Type

Instantaneous tripping current

B

above 3 In up to and including 5 In

C

above 5 In up to and including 10 In

D

above 10 In up to and including 20 In


Cheap Residual Current Device Mini Circuit Breaker 2 Pole RCCB 16A 25A 40A 63A for sale