Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home > Air Conditioners >

300W Outdoor Network Cabinet Heat Exchanger Low Noise ISO9001 CE Certification

Categories Enclosure Heat Exchanger
Brand Name: ESTEL
Model Number: HE06-30SEH/T
Certification: ISO9001, CE, 3C, FCC, TLC
Place of Origin: Shenzhen, China (Mainland)
MOQ: 1
Price: negotiation
Payment Terms: T/T, L/C, etc
Supply Ability: 12,000 sets per month
Delivery Time: 10-15 working days
Packaging Details: carton + foam + wooden case +pallet
Cooling Method: heat pipe, passive cooling
Installation Mode: top mounted
Protection Level: IP55
Cover Material: galvanized steel
Rated Input Power: 46W
Rated Input Current: 0.95A
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

300W Outdoor Network Cabinet Heat Exchanger Low Noise ISO9001 CE Certification


300W Outdoor Network Cabinet Heat Exchanger Low Noise ISO9001 CE Certification


Quick Details:


Place of Origin: Shenzhen, China (Mainland)Rated Heat Exchange Capacity: 30W/K
Brand Name: ESTELRated Heating Capacity:300W
Model: HE06-30SEH/TInput Voltage: DC48V
Product Name: Outdoor Telecom Cabinet Heat ExchangerRated Input Current: 0.95A
Certification: ISO9001, CE, 3C, FCC, TLCRated Input Power: 46W
Protection Level: IP55Noise: 50dB
Installation Mode: top mountedDimension W×D×H: 482.6×500×180 mm
Support OEMType: air to air heat exchanger

Payment & Shipping Terms:


Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:T/T, L/C, etc
Supply Ability:12,000 sets per month
Delivery Time:10-15 working days
Packaging Details:carton + foam + wooden case +pallet

1. Technical Parameters


ModelHE06-30SEH/T
Performance Parameters
Rated Voltage (V)DC48V
Rated Current (A)0.95
Heat Exchange Capacity (W)300
Heater Power (W)300
Rated Power (W)46
Circulation Air Volume (m3/h)200
Noise (dB(A))50
RefrigerantMixed Liquid
Working Temperature-20°C ~ 55°C
Mechanical Parameters
Installation ModeTop Installed
Height (mm)180
Width (mm)482.6
Depth (mm)500
Controller Parameters
Working Voltage (V)DC36~72
Working Temperature and Humidity-20°C ~ +80°C, <90%RH
Temperature Control Accuracy (°C)0.1
Power Consumption (W)5
Communication ModeDry contact,RS485, RS232, GPRS

2. Description


The cabinet heat exchanger is designed for outdoor cabinet and control cabinet. It is applicable for the scenarios where internal equipment of the cabinet emits a large quantity of heat and the normal operating temperature of internal equipment is higher than the environment temperature and where the indoor environment needs to be isolated from the outdoor completely.


The heat exchanger for outdoor cabinet adapts to the harsh environment. The complete isolation between the indoor environment and the outdoor environment can prevent the dust, hazardous gases, and humid gases from entering the cabinet, thus ensuring the internal cleanliness of the cabinet.


3. Application


The cabinet heat exchanger is widely used for outdoor telecom cabinet, outdoor battery cabinet, outdoor UPS cabinet, outdoor power cabinet, electric cabinet and industry cabinet,etc.

4. Features


(1) Independent energy saving control technology greatly reduces working energy consumption;

(2) LCD control board provides easy installation and maintenance;

(3) Perfect monitoring function, effective monitoring and management on air conditioner operation;

(4) Integrated design, easy for installation and maintenance;

(5) Protection Level: IP55, anti- corrosion, long service life;

(6) Using DC high efficient fans, greatly lower the product noise, environment friendly;

(7) Good energy saving performance, short investment payback period;

(8) Long service life: more than 10 years, easy maintenance and low cost;

(9) With RS485 remote monitoring interface, fault detection and alarm can be transmitted to monitoring center through controller.


5. Electrical Wiring Diagram


Wiring Ports:

0V -48V: power supply input (voltage input: DC36 - 65V)

A+ B- SGND: RS485 communication interface

AL1 AL2: general alarm output

F+ F- : auxiliary direct ventilation control output (output voltage: DC48V)


6. System Control Wiring Diagram


7. Packing and Shipping



Our Delivery Agent


The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


8. Our Contact Information


Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

Cheap 300W Outdoor Network Cabinet Heat Exchanger Low Noise ISO9001 CE Certification for sale
Send your message to this supplier
 
*From:
*To: Tianjin Estel Electronic Science and Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0