JDZ10-10(A) Cast Resin Epoxy Resin Indoor High Voltage Current
The instruments are mostly needle-type current voltmeters, so the
secondary current of the current Transformer is mostly
amped-grade(E. G. 5). With the development of the times, most of
the power measurements have reached the digital, and the computer
sampling signal is usually mA(0-5V, 4-20mA, etc.). The secondary
current of the micro current Transformer is milliampere, which acts
as a bridge between the large Transformer and the sample. The
miniature current Transformer is called the "current Transformer
for equipment". (`` Instrument Current Transformer "has a meaning
that is used in laboratories for multicurrent than precise current
Transformers, generally used to extend the meter range. ) The
circuit diagram of current Transformer is similar to that of
transformer, which is based on electromagnetic induction.
The primary winding is called the primary winding(or the primary
winding). The N2 connection measuring instrument of winding is
called secondary winding(or secondary winding, secondary winding).
The current ratio between primary winding current I1 and secondary
winding I2 is called the actual current ratio K. The current ratio
of a miniature current Transformer operating under rated operating
current is called rated current ratio, which is expressed by Kn. Kn
= I1n/I2n . General current Transformer structure principle: the
current Transformer structure is relatively simple, by mutual
insulation primary winding, secondary winding, iron core and frame,
shell, terminal, etc. The operating principle is basically the same
as that of Transformer. The number of turn(N1) of primary winding
is small, and the primary load current(I1) is directly connected to
power line.
Due to the equal amperes of primary winding and secondary winding,
the rated current Transformer has very little load impedance than
the current Transformer. The secondary winding is close to the
short-circuit state and is equivalent to a short-circuit running
Transformer. The core current Transformer does not have a primary
winding of its own structure. The load current leads from L1 to L2
act as a primary winding through a circular(or other shape) iron
core made of rolling Silicon steel. The second winding is wrapped
directly and evenly around the circular iron core, and the
secondary load of the current coil, such as the instrument, relay
and transmitter, forms a closed loop in series. On the other hand,
the less the number and the larger the ratio, the rated current is
more than I1/n: type I1 -- a rated current at the time of the
on-ramp; N-Number of heart-piercing.
Rated Voltage Ratio | Accuracy class | Insulation Level |
3000/100 , 10000/100/220 | 0.2/0.5/1/3 , 0.2/0.2 | 7.2/36/60kV |
| | |