Brand Name: Tianan Electric
Model Number: ZBW20(JBW)-12
Certification: CCC/ ISO9001
Place of Origin: CHINA
Capacity: 30—1600kVA
High voltage: 12KV
Low voltage: 400V
HV units: SF6 RMU
Shell Material: Aluminum Alloy
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

11kV Prefabricated Packaged Substation , Combined Substation

Structure characteristic:

This product has the advantages of smaller volume,compact structure,high heat insulation and ventilation function,dust-proof,prevent small animal to enter,moist-proof,beautiful appearance and convenient to maintenance, we can choose cold-rolled steel plate,compound color plate and other material to make up enclosure.
All the black material of substation are taken surface anticorrosive treatment, it will guarantee that product will be not corroded for a long time.
HV side use HXGN26-12(F), with complete operation mistake prevention function.

Main technical parameters

Technical data of HXGN26-12(F) RMU (equipped with FN26-12 SF6 Load Switch), see table 1
Table 1

ItemsUnitParameter
Rated voltagekV12
Rated frequencyHz50
Rated current of main busbarA630
Rated short time withstand current of main circuit and earth circuitkA/s25/2
Rated peak withstand current of main circuit and earth circuitkA63
Rated short circuit making current of main circuit and earth circuitkA50
Full capacity breaking times of load switchTimes100
Fuse breaking currentkA31.5 40
Mechanical enduranceTimes10000
1 min power frequency withstand voltage (r.m.s)
phase to earth,between phase/ isolating distance
kV42/48
Lighting impulse withstand voltage(peak)
phase to earth,between phase/ isolating distance
kV75/85
Secondary circuit 1 min power frequency withstand voltagekV2



Technical data of FN26-12 SF6 Load Switch, see table 2
Table 2

ItemsUnitParameter
Rated voltagekV12
Rated currentA630
Rated frequencyHz50
1 min power frequency withstand voltage (r.m.s)
phase to earth,between phase/ isolating distance
kV42/48
Lighting impulse withstand voltage(peak)
phase to earth,between phase/ isolating distance
kV75/85
Rated short time withstand currentkA/s25/2
Rated peak withstand currentkA63
Rated short circuit making currentkA50
Rated active load breaking currentA/times630/100
Rated cable charging currentA10
Rated un-load transformer breaking current1600KVA transformer un-load current
Main circuit resistanceµΩ≤85
Rated SF6 gas pressure (in 20ºC)Mpa0.04
Mechanical enduranceTimes10000


Switch parameter on the LV side
Main switch adopts TANW1,MT series, shunt switch adopts TANM1,NSX series, see table 3
Table 3

TypeLimit short circuit breaking capacity Icu (400V) KARunning short circuit breaking capacity Ics (400V) KA
TANW1-20008050
MT08N14242
MT10N14242
MT12N14242
MT206565
TANM1-100S3517.5
TANM1-225S3517.5
TANM-400S5025
TANM-630S5025
TANM1-800S7550
NSX-100N5050
NSX-250N5050
NSX-400N5050
NSX-630N5050



Structure and appearance:

1. Substation base plate and supporting structure adopt U-steel and angle steel, it has higher mechanical intensity, enclosure adopts cold-rolled steel plate or compound color plate. It has beautiful appearance that there are no threaded connection or rivet connection from the exposed surface.
2. Use clapboard to divide into independent room between each room of substation.
3. In order to observe and maintain, LV room and HV room have lighting device.
4. Reversible connecting parts of substation adopt rubber belt to seal, with good damp-proof capacity.
5. HV room is equipped with HXGN26-12(F) RMU, and also with SF6 load switch,fuse(adopts circuit breaker,lighting arrester,earth switch and mechanical interlock device if it required,.

6. If adopts HV measuring, it is also equipped with voltage transformer,current transformer and measuring meter.
7. Each LV elements in LV room should be frontal arranged.

8.Instrument room on the top, it has observing window on the front. each element has independent and removable plate,can be convenient to maintain.
According to the requirement of reactive compensation, it should be equipped electric device, its capacity is 15~20% of transformer.