Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home > Ball Valves >

Battery Cooling Brushless DC Water Pumps 24V 30LPM For Auxiliary Heating Cycles

Categories Brushless DC Water Pump
Brand Name: junqi
Model Number: OWP-BL93-301
Certification: IS9001, TS16949,CE
Place of Origin: China
MOQ: 5 sets
Price: Negotialbe
Payment Terms: T/T, Western Union, Paypal
Supply Ability: 1000set/month
Delivery Time: base on order,
Packaging Details: suitable for export
Model: OWP-BL93-301
Material: Aluminium alloy
Voltage: 24VDC
Power: 100W
Rated Flow Rate: 1800L/H,
Max Head: 9M
Application: Hybrid bus, electric vehicles
Usage: Coolant
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Battery Cooling Brushless DC Water Pumps 24V 30LPM For Auxiliary Heating Cycles

    24V 30LPM Brushless DC Water Pumps using for The Battery Cooling and Auxiliary Heating Cycles

    Boosting/circulation/Variable-frequency/Low-noise/shield pump/PWM control/ Fault feedback


    OWP-BL93-301 100W BLDC Water Pump With PWM Control And Error Diagnostics colant pump,glycol pump,bldc water pump

    ■ Applications
    Widely used in hybrid bus, hybrid passenger car, electric vehicles, trains, and ships and other heating and cooling circulation system.

    ■ Features
    ◆Magnetic force transmission (shield pump structure)Centrifugal pump
    ◆High efficiency brushless DC motor, low power consumption, high efficiency, long service life.
    ◆With wide range operating temperature
    ◆PWM signal speed controlling
    ◆With constant flow controlling
    ◆Reverse polarity protection
    ◆Dry running protection
    ◆Over Voltage, over current protection
    ◆Overload, over temperature protection

    ■ Technical description (related parts in contact with the liquid)
    Pump head housing: PPS+GF
    Impeller: PPS+GF
    Shield cavity: PPS+GF
    Shaft sleeve: Carbon resin composite materials
    Shaft: stainless steel shaft
    Magnet housing: nylon plastic capsulation
    Seal ring: EPDM

    ■ Driving device (Including motor)
    Driving electromagnet: nylon plastic capsulated magnet
    Screws and nuts: SUS 304 stainless steel
    Driving Motor : brushless motor
    Motor wire frame :PPA GF
    Pump housing: Die-casting aluminum case with sandblasting and impregnation treatment

    Bracket: Steel with powder coating
    Bracket hoop: US 304 stainless steel+ Damping rubber ring
    Waterproof based on IP68 rating (en60529)
    Connector model: AMP282106-1(matched Plug AMP282088-1)
    Nozzle diameter:22.4mm (inner diameter:16mm)

    Model Specifications
    OWP-BL93-301 (24VDC)
    Mounting instruction
    OWP-BL93-300 series pumps are centrifugal pumps which require pre-filled,
    The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on .
    1: Pump should not be dry-running, even though it can dry-running for 30 seconds (after 30 seconds dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.

    2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.

    3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).

    4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .

    5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )

    6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees
    Elbow (see figure 2).

    7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium .

    Temperature parameter
    Medium liquid temperature: -40℃ to +85℃ (-40°F to + 185°F)
    Working ambient temperature: -40℃ to +85℃ (-40°F to +185°F) Humidity ≤90%
    Storage temperature: -40℃ to +70℃ (-40°F to +158°F) (up to 100 ℃, but it will shorten the service life)
    System pressure
    -0.2 to 2.5 bar ( 100℃ (212°F).
    The service life is more than 20,000 hours based on the rated voltage and 36℃(86°F) ambient temperature.
    Voltage range
    Rated 12V water pump, workable range 9V - 16V
    Rated 24V water pump, workable range 18V - 30V
    Although the motor can be used in a wide range of voltage and temperature, but excessive or too low voltage and temperature will affect the service life of the motor, the pump can not be exposed to thermal radiation ambient.

    Medium liquid: pure water, liquid mixture (Water with below 60% glycol)


    Electrical parameter

    Working Voltage

    (VDC)

    Rated power

    (W)

    Rated flow

    (L/H)

    Dimensions

    (mm)

    Weight

    (g)

    18-30V(24V)

    100WQ=1800L/H H=9M148*90*1321.12KG









    Connector model and the corresponding electrical properties (see figure 3):

    AMP282106-11 (Black)2 (Yellow)3 (Blue)4 (Black)
    (matched Plug
    AMP282109-1)
    GNDFault feedbackPWM+24V








    PWM character


    Duty CycleDescriptionRemark:
    1:PWM duty cycle metrical error 2%
    2:PWM voltage:24VDC/12VDC(same as pump voltage)
    frequency:50-1000KHz
    3: Recommended PWM stop duty:10%
    4: Recommended 0% duty as PWM disconnect
    0%≤duty≤10%Stop state
    11%≤duty≤55%Min speed running
    56%≤duty≤90%PWM mode
    (Linear speed control range)
    91%≤duty≤100%Max speed running



    Attentions
    1. Working ambient temperature:-40℃--85℃, should try to avoid close to three-element catalytic, gas discharge pipe system and engine during the installation, ensure the working environment temperature.
    2.The installation position of the water pump should as much as possible close to the low water level , to extend the service life of the pump.
    4. Please use the pump far from the dusty environment, the dust is harmful to reduce the service life
    5. Pay attention to the purity of the water, avoid to jam and impeller-blocked to reduce the service life of pump
    Performance parameter

    • External dimension

    Product Tags:heavy duty electric water pump electric engine water pump

    Cheap Battery Cooling Brushless DC Water Pumps 24V 30LPM For Auxiliary Heating Cycles for sale
    Send your message to this supplier
     
    *From:
    *To: Changzhou Junqi International Trade Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0