Sign In | Join Free | My ecer.jp
ecer.jp
Products
Search by Category
Home >

Horizontal Hydronic FCU In HVAC System Carrier Fan Coil Units For Cooling And Heating

Categories Ceiling Concealed Fan Coil Unit
Brand Name: XUGUANG
Model Number: FP
Certification: ISO9001
Place of Origin: CHINA
MOQ: 1
Packaging Details: carton
Type: Fan Coil Unit,Water system,Under ceiling type FCU terminal air conditioner
Condition: New
Mounting: Ceiling Mount,Horizontal concealed
Operating voltage: 220V,220V/1P/50HZ
After-sales service provided: Online support,Video technical support
Cooling capacity: 1.8-12.6KW
Heating capacity: 2.7-18.9KW
Product name: fan coil
Air flow: 200-1400 CFM
Warranty: 12~36 months
Noise: Low Noise
Airflow: 200-1400 CFM
Material: Galvanized Steel Sheet,Galvanized plate shell,Copper pipe and aluminium fins
Function: Air Conditioner Terminal Unit,Air heating / air conditioning
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Horizontal Hydronic FCU In HVAC System Carrier Fan Coil Units For Cooling And Heating

    brief introduction

    Fan coil unit is mainly composed of centrifugal fan, coil heat exchanger, etc, is the end of the central air conditioning system products, he is widely used in hotels, restaurants, factories, hospitals, exhibition halls, shopping malls and office buildings more room or large space such as industrial and civil building, air conditioning occasion, to meet the requirements of cooling dehumidification, heating, etc, for people to create a pure and fresh, quiet, four spring-like working and living environment


    Fan coil unit features

    High performance and efficiency

    The surface cooler is made of high quality and high efficiency copper tube through double flanged window aluminum fin mechanical expansion knot, the surface of the fin hydrophilic treatment, low wind resistance, high efficiency

    Delicate structure, sturdy and durable

    Shell molded, delicate appearance, high strength. The shell is zero spangle, environmental - friendly galvanized sheet

    Stable, energy saving

    The motor is provided with heating and power off protection device, and the bearing does not need lubricating oil. The fan has three speed regulation, which can be set according to user's requirement

    Advanced technology, low noise

    There is no welding point on the whole fan impeller, and the wheel frame ring is tightly combined without deformation, which not only reduces the noise of the unit, but also effectively ensures the long-term stable operation of the unit

    Easy adjustment, maintenance aspect

    The humanized design of the unit makes it easy for users to maintain and repair

    Installation instructions

    Vertical unit is installed on the horizontal surface, keep vertical, do not tilt; Horizontal unit, the installation of the four lifting point must keep the level of the unit, to prevent condensation water caused by the end of the condensate pipe lifting overflow

    In and out of the water pipe should be equipped with valves, in order to facilitate adjustment and maintenance, and must pay attention to the entry and exit of the water pipe cleaning and insulation work, condensate plastic pipe shall not be compressed, there shall be no dead bend, to ensure the use of condensate smooth

    The unit three gear speed regulation switch, the opening type should start from the high grade, then carries on the other grade choice, when many machines share, must single machine control

    Unit power: 220V, 50Hz ac motor. If the unit has difficulty starting, be sure to check whether the power supply is normal and whether the wind turbine and its housing are contacted

    The cold water temperature of the unit shall not be lower than 7 c in summer, and the hot water temperature shall not be higher than 80 c in winter,the water quality of the cold and hot water sources used must be considered and softened

    The unit is allowed to use a maximum pressure of 1.6Mpa

    The filter should be cleaned regularly

    The heat exchanger should be cleaned regularly to ensure good heat transfer

    If the unit is installed in a hidden place, there should be an access door for easy maintenance

    The power should be cut off during maintenance

    The ordering guide

    Choose fan-coil unit, please specify the product specifications and models and the inlet and outlet of the left-right type

    When selecting the air return box for ceiling concealed fan coil units with installation, it shall be indicated whether the return air is under return air or after return air

    Please indicate the low static pressure (12Pa) and high static pressure (30Pa, 50Pa) of ceiling concealed fan coil unit when ordering.If no special requirements, at low static pressure delivery

    Cheap Horizontal Hydronic FCU In HVAC System Carrier Fan Coil Units For Cooling And Heating for sale
    Send your message to this supplier
     
    *From:
    *To: SHANDONG XUGUANG AIR CONDITIONING EQUIPMENT CO.LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0